OPTICA
300
SHOWER MIXER/TRANSFER VALVE
INSTALLATION INSTRUCTIONS
INSTALLER: LEAVE THIS INSTRUCTION MANUAL FOR OWNER'S/USER'S REFERENCE
WARNING: This system/device must be set by the installer to ensure safe, maximum temperature. Any change in
the setting may raise the discharge temperature above the limit considered safe and may lead to scalds.
CAUTION: As the installer of this valve, it is your responsibility to properly install and adjust this valve per the
instructions given. This valve does not automatically adjust for inlet temperature changes, therefore, it is necessary
to adjust the Rotational Limit Stop at the time of installation. You must inform the owner/user of this requirement by
following the instructions below. After installation and adjustment, you must write in the temperature and the date
you adjusted the Rotational Limit Stop on the warning label provided and apply or attach it to the hot water heater.
Be sure this instruction sheet is delivered to the owner/user.
WARNING: This pressure balanced bath valve is designed to minimize the effects of outlet water temperature
changes due to inlet pressure changes, commonly caused by dishwashers, washing machines, toilets and the like.
It may not provide protection from scalding when there is a failure of other temperature controlling devices elsewhere
in the plumbing system if the Rotational Limit Stop is not properly set, or if the hot water temperature is changed after
the Rotational Limit Stop is set, or if the water inlet temperature changes due to seasonal changes.
OPTICA 300
FINISHING WALL
TILE (FINISH SURFACE)
FACEPLATE (SEALANT NOT PROVIDED)
TRIM SLEEVE OF TRANSFER VALVE
GASKET
TRIM SLEEVE
2-3/8" DIA.
2-3/8" DIA.
WOOD CROSS MEMBER
REAR VIEW
(FRONT HAS RED
AND BLUE DOTS)
GASKET
COPPER PIPE (NOT PROVIDED)
REAR VIEW
SEALANT (SILICONE) ON BACKSIDE OF
FACEPLATE
FEMALE THREAD TO SWEAT ADAPTOR
(NOT PROVIDED)
LEFT-HAND THREAD TO
SWEAT ADAPTOR (NOT PROVIDED)
4-15/16" MINIMUM
SEALANT (100% SILICONE) ON BACKSIDE OF
FACEPLATE (SEALANT NOT PROVIDED)
NOTE: WHEN INSTALLING BAND, RING, ROPE
OR FACETED HANDLE, PULL TRIM SLEEVE OUT
TO MEET HANDLE.
PLASTER GUARD
©1995 Jacuzzi Whirlpool Bath G570000 D 12/06 Page 1
Vista de página 0
1 2 3 4 5 6

Resumo do Conteúdo

Página 1 - INSTALLATION INSTRUCTIONS

OPTICA™ 300SHOWER MIXER/TRANSFER VALVEINSTALLATION INSTRUCTIONSINSTALLER: LEAVE THIS INSTRUCTION MANUAL FOR OWNER'S/USER'S REFERENCEWARNING

Página 2

INSTALLATION INSTRUCTIONSWARNING: Failure to follow these instructions could prevent the mixer/transfer valve from functioning properly.1. Shut

Página 3 - Rotational Limit Stop

9. Flush your system prior to installing the shower head. Place handle on valve stem and turn handle to full mix position. Turn ON water s

Página 4

Faucet leaks from bath spout/showerhead – SHUT OFF WATER SUPPLIESReplace seats and springs – Repair Kit RP4993. Check conditions of lower o-rings an

Página 5

1st Position2nd Position 50 70 50 70 70 70 40 853rd Position 61 79 67 83 74 89 70 1014th Position 68 83 75 90 84 97 84 1105th

Página 6 - This page left blank

Jacuzzi Whirlpool Bath 14801 Quorum Dr., Suite 400, Dallas, TX 75254 Service Support: Call 1-800-288-4002 ©1995 Jacuzzi Whirlpool Bath G570000